DC POWER BANKS
SUPREME POWER INTELLIGENT HIGH FREQUENCY SWITCHING DC POWER BANKS
Model # SP GZCXDW-5
These units can be used in operating applications where voltage is 500KV or lower
Model # SP GZCXDW-5
These units can be used in operating applications where voltage is 500KV or lower
Supreme Power Intelligent High Frequency Switching DC Power Banks were developed over several years research in practical applications testing of DC power systems for creation of this improved unattended power system.
New improvements include :
New improvements include :

High Frequency On-Off
Micro-Computer Communications
Fully Automated
Low maintaince
Uncomplicated design
Replacement of power module even on "Hot Lines"
Designed to remotely control measurement of important electric functions and communicate to units by computer interfaces.
Easy to operate
Complete module replacement and replacement by one person
(Pull out module and insert new one)
Complete computer monitoring and control from remote location
Technologically advanced automation

AC In-put Unit
Charging Unit
Power Out-Put Unit
Voltage regulating unit
Insulation monitoring Unit
Storage battery
Faulty battery alert
Faulty Check Unit alert
Micro Processor Intellegent Monitoring Unit
Examples of LED Light Touch Screen Control Panel Below

Storage Battery in separate compartment from all components
2 circuited AC In-Puts for back-up if one is faulty or load is high
Automatically switchs to spare AC In-Put
Distributs power evenly from on circuit to the other
Charging unit and Power Out-Put has switch power module and N=1 redundancy design allocated
Charging unit and Power Out-Put independently circuited and set for safety, security and reliabity
Monitoring unit consistes of high performance module with concentrated controller and Lighted LED Touch Control Screen.
Working states, parameters, signals and data of the monitoring system are displayed, shown and detected through RS232 or RS485 interface.
Cautions:
Micro-Computer Communications
Fully Automated
Low maintaince
Uncomplicated design
Replacement of power module even on "Hot Lines"
Designed to remotely control measurement of important electric functions and communicate to units by computer interfaces.
Easy to operate
Complete module replacement and replacement by one person
(Pull out module and insert new one)
Complete computer monitoring and control from remote location
Technologically advanced automation

Composed of:
AC In-put Unit
Charging Unit
Power Out-Put Unit
Voltage regulating unit
Insulation monitoring Unit
Storage battery
Faulty battery alert
Faulty Check Unit alert
Micro Processor Intellegent Monitoring Unit
Examples of LED Light Touch Screen Control Panel Below
| DC Touch Control Panel-LED Lighted | ||
| System state: faulty | Next Fuction/Page | Quit |
| Composite Busbar 1st: 245.5 V | ||
| Control Busbar 1st: :221.0 V | Main Window | |
| Battery 1st: 245.5 V | ||
| Battery 1st: -21.0 A | Information Inquiry | |
| System setting | ||
| Battery 1st: Floating Charge | System Control |
| DC Touch Control Panel-LED Lighted | ||
| AC Parameter | DC Parameter | Quit |
| Module Parameter | Current Faulty | Main Window Information |
| Insulation Monitoring | History Faulty | Information Inquiry |
| System Setting | System Control | System Setting |
| Battery Logging | Discharge Metering | System Control |
Actual Picture of LED Touch Screen Control Panel

DC LED Control Panel Information:
Storage Battery in separate compartment from all components
2 circuited AC In-Puts for back-up if one is faulty or load is high
Automatically switchs to spare AC In-Put
Distributs power evenly from on circuit to the other
Charging unit and Power Out-Put has switch power module and N=1 redundancy design allocated
Charging unit and Power Out-Put independently circuited and set for safety, security and reliabity
Monitoring unit consistes of high performance module with concentrated controller and Lighted LED Touch Control Screen.
Working states, parameters, signals and data of the monitoring system are displayed, shown and detected through RS232 or RS485 interface.
Climate Conditions/ Working Enviroment/ Limitations:
Cautions:
Use no more than 3,000 meters above sea level
Temperature ranges: -10 C to ~+ 15 C
Relative humidy NOT HIGHER than 90%
Keep from vibrations, shock and strong electromagnetic feilds
Do not use in areas of heavy dirt, explosive fumes or material, corrisive liquids, or air born corrisive metal powders
Place on level surface
Vertical gradient of no more than 5 degrees
See More Technical Data Here!
Temperature ranges: -10 C to ~+ 15 C
Relative humidy NOT HIGHER than 90%
Keep from vibrations, shock and strong electromagnetic feilds
Do not use in areas of heavy dirt, explosive fumes or material, corrisive liquids, or air born corrisive metal powders
Place on level surface
Vertical gradient of no more than 5 degrees
See More Technical Data Here!
DC panel Performance Data-Page 2
DC Performance Data-Page 3
Previous page: Battery Accessories
Next page: DC Panel Page 2